{"id":819,"date":"2014-09-08T12:10:09","date_gmt":"2014-09-08T10:10:09","guid":{"rendered":"https:\/\/www.argosengineering.it\/?page_id=819"},"modified":"2014-09-08T12:10:09","modified_gmt":"2014-09-08T10:10:09","slug":"hvac-systems-design","status":"publish","type":"page","link":"https:\/\/www.argosengineering.it\/en\/sectors\/railways\/hvac-systems-design\/","title":{"rendered":"HVAC Systems Design"},"content":{"rendered":"<p><em><strong>ARGOS Engineering<\/strong><\/em>\u00a0has gain many years of experience in design and development on HVAC Systems for railway vehicles. In 2001 we have been commisioned for the re-design of the <strong>HVAC of Tram Sirio Athens<\/strong> of Ansaldobreda by re-positionning of all the components (formerly fitted on the vehicle roof) inside a stand-alone module; this experience brought Argos to be commissioned for all the activities linked to the design and lay-out definition of the <strong>Chiller air conditioning plant<\/strong> inside the vehicle with Type and Functional Tests in Climatic Chamber on several vehicles of Tram Sirio Fleet.<\/p>\n<p>&nbsp;<\/p>\n<div id=\"attachment_367\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-1.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-367\" class=\"size-medium wp-image-367\" title=\"Tram Sirio Athens - HVAC System Roof Module\" alt=\"Tram Sirio Athens - HVAC System Roof Module\" src=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-1-300x212.jpg\" width=\"300\" height=\"212\" srcset=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-1-300x212.jpg 300w, https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-1.jpg 656w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-367\" class=\"wp-caption-text\">Tram Sirio Athens &#8211; HVAC System Roof Module<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_369\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-3.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-369\" class=\"size-medium wp-image-369 \" title=\"Tram Sirio Athens - HVAC System Roof Module handling\" alt=\"Tram Sirio Athens - HVAC System Roof Module handling\" src=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-3-300x212.jpg\" width=\"300\" height=\"212\" srcset=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-3-300x212.jpg 300w, https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-3.jpg 552w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-369\" class=\"wp-caption-text\">Tram Sirio Athens &#8211; HVAC System Roof Module handling<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_370\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-4.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-370\" class=\"size-medium wp-image-370\" title=\"Tram Sirio Athens - HVAC System Assembly without carters\" alt=\"Tram Sirio Athens - HVAC System Assembly without carters\" src=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-4-300x216.jpg\" width=\"300\" height=\"216\" srcset=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-4-300x216.jpg 300w, https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-4.jpg 704w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-370\" class=\"wp-caption-text\">Tram Sirio Athens &#8211; HVAC System Assembly without carters<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_368\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-2.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-368\" class=\"size-medium wp-image-368\" title=\"Tram Sirio Athens - HVAC System Detail\" alt=\"Tram Sirio Athens - HVAC System Detail\" src=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-2-300x241.jpg\" width=\"300\" height=\"241\" srcset=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-2-300x241.jpg 300w, https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Atene-2.jpg 496w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-368\" class=\"wp-caption-text\">Tram Sirio Athens &#8211; HVAC System Detail<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>Starting from 2003 Argos has developped the plant engineerization on variuos Sirio vehicles like Naples, Bergamo, Guthenburg: for the latter, we have managed design and prototype of Driver&#8217;s Cab HVAC with Climatic Chamber Tests.<\/p>\n<div id=\"attachment_375\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-21.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-375\" class=\"size-medium wp-image-375\" title=\"Tram Sirio - Air distribution in the passenger coaches\" alt=\"Tram Sirio - Air distribution in the passenger coaches\" src=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-21-300x252.jpg\" width=\"300\" height=\"252\" srcset=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-21-300x252.jpg 300w, https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-21.jpg 515w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-375\" class=\"wp-caption-text\">Tram Sirio &#8211; Air distribution in the passenger coaches<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_376\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-31.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-376\" class=\"size-medium wp-image-376\" title=\"Tram Sirio - Piping for refrigerating fluid distribution\" alt=\"Tram Sirio - Piping for refrigerating fluid distribution\" src=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-31-300x197.jpg\" width=\"300\" height=\"197\" srcset=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-31-300x197.jpg 300w, https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-31.jpg 687w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-376\" class=\"wp-caption-text\">Tram Sirio &#8211; Piping for refrigerating fluid distribution<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_377\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-4.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-377\" class=\"size-medium wp-image-377\" title=\"Tram Sirio - In-coach distribution system\" alt=\"Tram Sirio - In-coach distribution system\" src=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-4-300x258.jpg\" width=\"300\" height=\"258\" srcset=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-4-300x258.jpg 300w, https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-4.jpg 842w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-377\" class=\"wp-caption-text\">Tram Sirio &#8211; In-coach distribution system<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_378\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-5.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-378\" class=\"size-medium wp-image-378\" title=\"Tram Sirio - In-coach distribution system with interior lining integration\" alt=\"Tram Sirio - In-coach distribution system with interior lining integration\" src=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-5-300x212.jpg\" width=\"300\" height=\"212\" srcset=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-5-300x212.jpg 300w, https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/Sirio-5.jpg 601w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-378\" class=\"wp-caption-text\">Tram Sirio &#8211; In-coach distribution system with interior lining integration<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_380\" style=\"width: 258px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-GTB-1.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-380\" class=\"size-medium wp-image-380\" title=\"Tram Sirio Guthenburg - Driver's Cab HVAC System\" alt=\"Tram Sirio Guthenburg - Driver's Cab HVAC System\" src=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-GTB-1-248x300.jpg\" width=\"248\" height=\"300\" srcset=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-GTB-1-248x300.jpg 248w, https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-GTB-1.jpg 736w\" sizes=\"auto, (max-width: 248px) 100vw, 248px\" \/><\/a><p id=\"caption-attachment-380\" class=\"wp-caption-text\">Tram Sirio Guthenburg &#8211; Driver&#8217;s Cab HVAC System<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><em><strong>ARGOS Engineering<\/strong><\/em>\u00a0was also committed by Ansaldobreda for the design and development of the distribution system of air conditionned for vehicles Metro Los Angeles, and for the 3D modelling of air ducts on V250 complete with CFD analysis.<\/p>\n<p>&nbsp;<\/p>\n<div id=\"attachment_383\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-Los-Angeles-1.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-383\" class=\"size-medium wp-image-383\" title=\"Metro Los Angeles - Air distribution inside the vehicle\" alt=\"Metro Los Angeles - Air distribution inside the vehicle\" src=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-Los-Angeles-1-300x240.jpg\" width=\"300\" height=\"240\" srcset=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-Los-Angeles-1-300x240.jpg 300w, https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-Los-Angeles-1-1024x821.jpg 1024w, https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-Los-Angeles-1.jpg 1103w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-383\" class=\"wp-caption-text\">Metro Los Angeles &#8211; Air distribution inside the vehicle<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_384\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-Los-Angeles-2.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-384\" class=\"size-medium wp-image-384\" title=\"Metro Los Angeles - Air distribution inside the vehicle\" alt=\"Metro Los Angeles - Air distribution inside the vehicle\" src=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-Los-Angeles-2-300x212.jpg\" width=\"300\" height=\"212\" srcset=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-Los-Angeles-2-300x212.jpg 300w, https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-Los-Angeles-2.jpg 968w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-384\" class=\"wp-caption-text\">Metro Los Angeles &#8211; Air distribution inside the vehicle<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_385\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-V250.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-385\" class=\"size-medium wp-image-385\" title=\"V250 - Air distribution inside the vehicle\" alt=\"V250 - Air distribution inside the vehicle\" src=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-V250-300x300.jpg\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-V250-300x300.jpg 300w, https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-V250-150x150.jpg 150w, https:\/\/www.argosengineering.it\/wp-content\/uploads\/2014\/05\/HVAC-V250.jpg 625w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-385\" class=\"wp-caption-text\">V250 &#8211; Air distribution inside the vehicle<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>ARGOS Engineering\u00a0has gain many years of experience in design and development on HVAC Systems for railway vehicles. In 2001 we have been commisioned for the re-design of the HVAC of Tram Sirio Athens of Ansaldobreda by re-positionning of all the components (formerly fitted on the vehicle roof) inside a stand-alone module; this experience brought Argos [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":732,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-819","page","type-page","status-publish","czr-hentry"],"_links":{"self":[{"href":"https:\/\/www.argosengineering.it\/en\/wp-json\/wp\/v2\/pages\/819","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.argosengineering.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.argosengineering.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.argosengineering.it\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.argosengineering.it\/en\/wp-json\/wp\/v2\/comments?post=819"}],"version-history":[{"count":1,"href":"https:\/\/www.argosengineering.it\/en\/wp-json\/wp\/v2\/pages\/819\/revisions"}],"predecessor-version":[{"id":820,"href":"https:\/\/www.argosengineering.it\/en\/wp-json\/wp\/v2\/pages\/819\/revisions\/820"}],"up":[{"embeddable":true,"href":"https:\/\/www.argosengineering.it\/en\/wp-json\/wp\/v2\/pages\/732"}],"wp:attachment":[{"href":"https:\/\/www.argosengineering.it\/en\/wp-json\/wp\/v2\/media?parent=819"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}